Datacom Systems D56 Spezifikationen Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 108
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
Si5040
Rev. 1.3 53
Reset settings = 0000 0001
Register 10. RxLosCtrl
BitD7D6D5D4D3D2D1D0
Name sqmLosEn dLosEn[1:0] aLosEn
Type RRRRR/W R/W R/W
Bit Name Function
7:4 Reserved Read returns zero.
3sqmLosEnSignal Quality Monitor LOS Enable.
0 = Disabled.
1 = Signal Quality Monitor alarm causes an LOS alarm.
2:1 dLosEn[1:0] Digital LOS Enable Mode.
00 = Disabled.
01 = Digital LOS alarm is based on the consecutive number of zeros programmed in
Register 17.
10 = Digital LOS alarm is based on the consecutive number of ones programmed in Reg-
ister 17.
11 = Digital LOS alarm is based on the consecutive number of either zeros or ones pro-
grammed in Register 17.
0 aLosEn Analog LOS Enable.
0 = Disabled.
1 = Analog LOS alarm active.
Seitenansicht 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 107 108

Kommentare zu diesen Handbüchern

Keine Kommentare