Si5040
Rev. 1.3 5
2. Electrical Specifications
Figure 1. Voltage Measurement
Figure 2. Rise/Fall Time Measurement
Table 1. Recommended Operating Conditions
Parameter Symbol Test Condition
Min
1
Typ
Max
1
Unit
Ambient Temperature T
A
–40 25 95 C
Supply Voltage V
DD
2
1.62 1.80 1.89 V
LVTTL I/O Supply Voltage V
DDIO
1.62 — 3.63
V
Notes:
1. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions.
Typical values apply at nominal supply voltages and an operating temperature of 25 C unless otherwise stated.
2. Maximum power ramp-up time to reach V
DD
> 1.62 V should be less than 50 ms. Any ramp-up time slower than 50 ms
will require a software reset to ensure proper calibration of all internal circuits.
V
ISE
, V
OSE
V
ID
,V
OD
(V
ID
= 2V
ISE
)
Differential
I/Os
Differential
Voltage Swing
Single-Ended
Peak-to-Peak Voltage
Differential Peak-to-Peak Voltage
SIGNAL +
SIGNAL –
(SIGNAL +) – (SIGNAL –)
V
ICM
, V
OCM
V
t
All Differential IOs
t
F
t
R
80%
20%