Si5040
12 Rev. 1.3
Table 6. AC Characteristics–TD (Transmitter Input)
Parameter Symbol Test Condition Min Typ Max Unit
TX Path Data Rate 9.80 9.95 11.35 Gbps
Differential Input Return Loss SDD11
0.05–0.1 GHz 20 — — dB
0.1–5.5 GHz 8 — — dB
5.5–12 GHz See
Note
1
——dB
Common Mode Input Return Loss (TD) SCC11 0.1–15 GHz 3 — — dB
Total Non-DDJ
2
—0.45UI
PP
Total Jitter TJ — 0.65 UI
PP
Sinusoidal Jitter Tolerance
3
SJ — See
Figure 4
—UI
PP
Eye Mask (See Figure 5) X1 — — 0.325 UI
Eye Mask (See Figure 5) Y1 50 — — mV
Eye Mask (See Figure 5) Y2 — — 525 mV
Notes:
1. Return loss is given by the following equation: SDD11(dB) = 8–20.66Log10(f/5.5), with f in GHz.
2. Total jitter less ISI.
3. The jitter tolerance given in Figure 5 is in addition to the random and deterministic jitter given in this table.
Table 7. CMU Timing Modes
Mode Description Typical Jitter Gen. Recommended CMU Jitter
Transfer Bandwidth Setting
0 No Reference Clock or
Asynchronous Reference Clock
1,2
3.5 mUI
rms
380 kHz
1 Clean, synchronous
3
2.5 mUI
rms
380 kHz
2 Clean, asynchronous
1,3
2.5 mUI
rms
1.37 kHz
Notes:
1. Reference clock with frequency equal to Baud rate /64 ±100 ppm and phase noise as defined in XFP Specification 3.1,
Section 3.9.
2. Since the default bandwidth for this mode is 100 kHz, Register 134 [7:4] should be written to a “4” to set the bandwidth
to 380 kHz.
3. Clean reference clock with frequency equal to exactly Baud rate /64 and phase noise as defined in XFP Specification
3.1, Section 3.9.1. REFCLK input amplitude >650 mVppd.